Triple mouse M Double glass window, no artificial dura Behaving in Simon's 2-mode detection task Auditory expert. Window centered over PPC. =========================== 8/03/18 Imaging depth is 180um. Location should match RL. SNR is pretty bad. There is massive bleed through from the red channel into the green. Expression seems much brighter than Gcamp modulation. Can't really see much change by eye... Recording anyways just to see whether this might be useful. Should use much less virus the next time! Pretty good otherwise. Very little movement with licking. Started presenting visual trials with 20% probability after 65 performed trials. So annoying... everything else is really nice, behavior is good, virtually no drift / movement. Just barely any activity in the green channel. Something seems wrong with the animals eye: I can't see the pupil although the laser is clearly running. Usually the pupil should be illuminated. Maybe, this doesn't happen with the PPC window - check if the pupil can still be extracted... 70000 up 5 Switched to all vision after 345 performed trials. Animal got pretty disengaged somewhere in the middle of the session and behavior is not as good. Still at 75% audio detection though. =========================== 08/07/18 Imaging depth is 180um. Laser at 48%. Location should match edge of V1 - mostly posterior to RL. Very few modulated neurons. Very little motion, shielding is good. Pupil seems dark instead of bright. 25000 up 5 Bpod matlab crashed around frame 43000. Restarted. 90000 up 5 Switched to all vision after 230 performed trials in new session. Auditory detection ~73%/ Audio probability at 80%. Stopped after 310 performed trials in the second session. =========================== 08/08/18 Imaging depth is 180um. Location should match V1 - same location as yesterday. Laser at 50%. Signal is not great but see a little bit of modulation. Little motion, shielding is good. Pupil is dark again, maybe I can identify with the flickering of the laser - have a look at the current code and see. 13000 up 5 80000 up 5 Presented at 80% auditory probability. Switched to all vision after 440 performed trials. Stopped after 475 performed trials. Performance is good: 83% auditory, 55% visual. =========================== 08/10/18 Imaging depth is 180um. Location should match S1 - anterior to presumed PPC location. Laser power at 50%. Pupil might be a bit better. Laser is more visible here. Signal seems ok. Some cells seem quite stationary but I don't see them in the red channel. Big shadow in the center but should have enough neurons. See some movement modulation. Should be good. First 10 trials are visual, next 50 are audio, 80% audio probability after that. Not very motivated anymore after ~400 trials. Consider cutting the session there. Stopped after 426 performed trials. Auditory performance 74%, vision 53% =========================== 08/10/18 Imaging depth is 150um. Location should match RS - close to medial edge of the window. Pretty dark - Laser power at 55%. Had to change sinusiodal correction from 160 to 161. Would be good to know what that is determined by. See some modulation in the field. Won't have that many neurons but should be ok. Behavior is good. Switched to audiovisual after 65 performed trials. Visual prob. is 25%. Pupil is hard to see again but might be ok. Stopped after 500 performed trials. Performance is good: 86% audio, 56% vision =========================== 08/18/18 Imaging depth is 180um. Location should match S1 - anterior to presumed PPC location. Slightly more lateral than last time. Laser power at 55%. Shielding is good. Presenting 25% visual trials after 20 auditory trials. 12000 up 5 24000 up 5 76000 up 7 115000 up 3 Switched to vision after 390 performed trials. Stopped after 415 performed trials. Performance is good. 82% audio, 50% vision. =========================== 08/20/18 Imaging depth is 225um. Location should match RS - a bit more anterior than last time. Pretty dark - Laser power at 60%. See some active cells. Should be better than last recording. First 1-2 trials are at the wrong depth. Started at 205 by accident. Switched to 225 after. 15000 up 5 SWitched to audiovisual after 60 performed trials. visual prob is 25%. 20000 up 5 23000 down 10 28000 up 5 60000 down 5 All vision after 385 performed trials. Stopped after 425 performed trials. Performance is good: 81% audio, 50% vision. Should be a good session.