[System] ;Specifies global configuration settings for the instrument. InstrumentName = NB551387 ;Indicates the name of the instrument. [Flowcell] ;Configuration items for flow cell objects. ActualXEdgeOfSlide = -0.0775 ; ActualYEdgeOfSlide = -0.0201 ; Flowcell1XOffset = 0 ; Flowcell1YOffset = 0 ; [PreRunChecks] ;Pre-run Checks SkipRequiredSoftwareCheck = False ;Skip the check for required software. SkipNetworkConnectionCheck = False ;Skip the check network connection check. SkipNetworkDiskSpaceCheck = False ;Skip the check for sufficient disk space at the Output Folder location. SkipInstrumentDiskSpaceCheck = False ;Skip the check for sufficient disk space at the Run Folder location. SkipConsumablesLoadedCheck = False ;Skip the check for all consumables properly loaded. SkipBitErrorRateCheck = False ;Skip the Bit Error Rate check. SkipZStepAndSettleCheck = False ;Skip the check for Z stage step-and-settle times. SkipWasteBottleFullCheck = False ;Skip the check for the waste bottle not being full. SkipDoorsClosedCheck = False ;Skip the check for all doors closed. SkipBsmCheck = False ;Skip the BSM check. SkipValveResponseCheck = False ;Skip the valve response check. SkipFluidicsInitializationCheck = False ;Skip the check for the fluidics system being properly initialized. SkipImagingLimitsCheck = False ;Skip the imaging limits check. SkipTemperatureCheck = False ;Skip the check for proper temperature ramping. SkipFlowCellRegistrationCheck = False ;Skip the flow cell registration test SkipClipCheck = True ;Skip the objective clip check SkipTempSensorsCheck = False ;Skip the temperature sensors check. SkipFanCheck = False ;Skip the fan check. SkipAutoCenterCheck = False ;Skip the auto center check. SkipVerifyInputFilesCheck = False ;Skip the verify input files check. [ImagingModule.CameraModule1] ;Settings for the read head. FocusCenterZMm = 0.009562333 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.002519884 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 3.8 ;Camera exposure time in ms RelativeCameraPositionXUm = 12.39443 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = 0 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [ImagingModule.CameraModule2] ;Settings for the read head. FocusCenterZMm = -0.00664676 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.002573474 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 3.3 ;Camera exposure time in ms RelativeCameraPositionXUm = 0 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = 0 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [ImagingModule.CameraModule3] ;Settings for the read head. FocusCenterZMm = 0.00315614 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.002849778 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 3.2 ;Camera exposure time in ms RelativeCameraPositionXUm = -7.74622 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = 0 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [ImagingModule.CameraModule4] ;Settings for the read head. FocusCenterZMm = 0.009507536 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.00273548 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 2.8 ;Camera exposure time in ms RelativeCameraPositionXUm = -9.295464 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = 3.872871 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [ImagingModule.CameraModule5] ;Settings for the read head. FocusCenterZMm = 0.005238015 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.002372357 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 3.4 ;Camera exposure time in ms RelativeCameraPositionXUm = 8.52108 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = 14.71806 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [ImagingModule.CameraModule6] ;Settings for the read head. FocusCenterZMm = 0.01891159 ;Z position for the center of coarse and fine focus ChromatismRedToGreenDeltaZMm = -0.002573466 ;Delta-Z used for chromatism between the Red and Green channels. FocusLaserExposureMS = 2.8 ;Camera exposure time in ms RelativeCameraPositionXUm = 12.39443 ;Stores delta X value of this camera's position relative to the reference camera (camera 2). RelativeCameraPositionYUm = 10.84518 ;Stores delta Y value of this camera's position relative to the reference camera (camera 2). [Fluidics.FlowCellFluidics1.IxFlowCellTemp] ;Settings for the temp controller. TemperatureOffset = 0 ;Set the offset between the readback and flowcell. CalibrationLowTarget = 0 ;The temperature which is the set point for the low temperature calibration point. CalibrationLowMeasured = 0 ;The temperature the technician measured at the low temperature point during the calibration procedure. CalibrationHighTarget = 0 ;The temperature which is the set point for the high temperature calibration point. CalibrationHighMeasured = 0 ;The temperature the technician measured at the high temperature point during the calibration procedure. [Fluidics.FlowCellFluidics1.IxPressureSensor1] ;Settings for the pressure sensor. Gain = 67.82 ;Standard transducer calibration. Intercept = -19.2 ;Approximate intercept to be set at manufacturing. [Fluidics.FlowCellFluidics1.IxPressureSensor2] ;Settings for the pressure sensor. Gain = 67.82 ;Standard transducer calibration. Intercept = -19.2 ;Approximate intercept to be set at manufacturing.